It is impossible to pass VMware 2v0 621 vce exam without any help in the short term. Come to Ucertify soon and find the most advanced, correct and guaranteed VMware vmware 2v0 621 practice questions. You will get a surprising result by our Renew VMware Certified Professional 6 – Data Center Virtualization practice guides.

Q9. Deletion of an NFS datastore generates the following error: 

Sysinfo error on operation returned the following status: Busy 

Which step can be performed that will allow the deletion to complete successfully? 

A. Storage vMotion any virtual machines on the datastore to another location. 

B. Remove the datastore from the Storage DRS cluster in which it resides. 

C. Verify the value of the NFS.HeartbeatDelta is not set to 0. 

D. Suspend any running virtual machines and unmount the NFS datstore. 

Answer:


Q10. Which two settings are required for Virtual Machine Component Protection (VMCP) to protect from All Paths Down (APD) and Permanent Device Loss (PDL)? (Choose two.) 

A. Host Monitoring 

B. VM Restart Priority 

C. Virtual machine Monitoring 

D. Response for Host Isolation 

Answer: A,B 


Q11. When upgrading vCenter Server, an administrator notices that the upgrade fails at the vCenter Single Sign-On installation. 

What must be done to allow the upgrade to complete? 

A. Verify that the VMware Directory service can stop by manually restarting it. 

B. Verify that the vCenter Single Sign-On service can stop by manually restarting it. 

C. Uninstall vCenter Single Sign-On service. 

D. Uninstall the VMware Directory service. 

Answer:


Q12. Which two vCenter Server services are migrated automatically as part of an upgrade from a Distributed vCenter Server running 5.x? (Choose two.) 

A. vCenter Single Sign-on Service 

B. vSphere Web Client 

C. vSphere Inventory Service 

D. Storage Policy Based Management 

Answer: B,C 


Q13. In which two vsphere.local groups should an administrator avoid adding members? (Choose two.) 

A. SolutionUsers 

B. Administrators 

C. DCAdmins 

D. ExternalPDUsers 

Answer: A,B 


Q14. An administrator uses the df -h command and notices that an NFS datastore is reporting a 

capacity of 0 Bytes. 

What condition would cause this to occur? 

A. The NFS server on which the datastore resides is down. 

B. The datastore was mounted as Read/Write. 

C. The datastore was mounted as Read-Only. 

D. The datastore was created with NFS version 4.1. 

Answer:


Q15. An administrator is configuring the clock tolerance for the Single Sign-On token configuration policy and wants to define the time skew tolerance between a client and the domain controller clock. 

Which time measurement is used for the value? 

A. Milliseconds 

B. Seconds 

C. Minutes 

D. Hours 

Answer:


Q16. Refer to the Exhibit. 

An administrator has created the DRS cluster shown in the Exhibit. 

Based on the exhibit, which statement is true? 

A. Under CPU contention, Prod-VM1 receives four times the CPU resources than Test-VM1. 

B. The Prod-VM1 will always have more CPU resources than all other virtual machines. 

C. The Test-VM2 will always have less CPU resources than all other virtual machines. 

D. Under CPU contention, Test-VM1 will receive 25% of the total CPU resources. 

Answer: