we provide Download Check Point 156-115.77 study guide which are the best for clearing 156-115.77 test, and to get certified by Check Point Check Point Certified Security Master. The 156-115.77 Questions & Answers covers all the knowledge points of the real 156-115.77 exam. Crack your Check Point 156-115.77 Exam with latest dumps, guaranteed!

Q81. - (Topic 1) 

You are troubleshooting a Security Gateway, attempting to determine which chain is causing a problem. What command would you use to show all the chains through which traffic passed? 

A. [Expert@HostName]# fw ctl chain 

B. [Expert@HostName]# fw monitor -e "accept;" -p all 

C. [Expert@HostName]# fw ctl debug –m 

D. [Expert@HostName]# fw ctl zdebug all 

Answer:


Q82. - (Topic 5) 

How to check the overall SecureXL statistics: 

A. fwaccel on B. fwaccel stat 

C. cat /proc/ppk/statistics 

D. fwaccel conns 

Answer:


Q83. - (Topic 6) 

Which information CANNOT be displayed by issuing the command cat /proc/cpuinfo? 

A. CPU family 

B. NFS_Unstable 

C. fpu 

D. vendor_id 

Answer:


Q84. - (Topic 3) 

Your cluster member is showing a state of "Ready"..Which of the following is NOT a reason one would expect for this behaviour? 

A. One cluster member is configured for 32 bit and the other is configured for 64 bit 

B. CoreXL is configured differently on the two machines 

C. The firewall that is showing "Ready" has been upgraded but the other firewall has not yet been upgraded 

D. Firewall policy has not yet been installed to the firewall 

Answer:


Q85. - (Topic 3) 

Your customer has an R77 Multi-domain Management Server managing a mix of firewalls of R70 and R77 versions..A change was made to the file $FWDIR/lib/tables.def on one of the domains..However, it was found that the change was not applied to the R70 firewalls..What could be the problem? 

A. Changes to the table.def can only be applied to firewalls matching the Management Server version..The customer needs to upgrade the firewalls to the same version as the firewall. 

B. R70 is end of life and is not supported..Most functions will work, but modifying the table.def will not. 

C. In order to make changes on R70 machines you need work within GuiDBedit 

D. To support R70, the file in the compatibility directory should have been modified. 

Answer:


Q86. - (Topic 3) 

You run the command fw tab -t connections -s on both members in the cluster..Both members report differing values for "vals" and "peaks"..Which may NOT be a reason for this difference? 

A. Synchronization is not working between the two members 

B. SGMs in a 61k environment only sync selective parts of the connections table. 

C. Heavily used short-lived services have had synchronization disabled for performance improvement. 

D. Standby member does not synchronize until a failover is needed. 

Answer:


Q87. - (Topic 6) 

You are finding that some users are complaining about slow connection speed. You would like to review a summary of your connections, including which connections are accelerated and those that are not. What command could you use? 

A. fw ctl pstat 

B. fwaccel perf 

C. fw tab -t connections -s 

D. fwaccel stats -s 

Answer:


Q88. - (Topic 11) 

Jane wants to create a VPN using OSPF. Which VPN configuration would you recommend she use? 

A. Site-to-site VPN 

B. Domain-based VPN 

C. Route-based VPN 

D. Remote-access VPN 

Answer: